AQI and PM2.5 are not interchangeable numbers. PM2.5 describes fine particles and is commonly reported as a concentration in micrograms per cubic meter (µg/m³). AQI translates pollutant concentrations into an index. A display reading “PM2.5: 20” cannot be compared directly with one reading “AQI: 20.”
What does each number describe?
PM2.5 refers to particles no more than 2.5 micrometers in diameter. A concentration describes how much particle mass is present in a volume of air. The AQI is a communication scale, with separate conversions for different pollutants. EPA explains particulate matter.
| Label on the screen | What to look for next |
|---|---|
| PM2.5, µg/m³ | Averaging window, instrument or model, indoor or outdoor location |
| PM2.5 AQI | AQI system, breakpoint version and concentration averaging window |
| US AQI | Dominant pollutant; particles may not be the pollutant setting the headline value |
| Current AQI | Observation time and whether it is a NowCast, sensor estimate or model |
Which PM2.5 breakpoints apply in the US?
The EPA table below maps averaged PM2.5 concentration to AQI ranges. The Good range ends at 9.0 µg/m³ in the revised breakpoints. A calculator using 12.0 for that boundary is using an older US table. These are not instantaneous indoor exposure limits. EPA’s current breakpoint table.
| PM2.5 concentration (µg/m³) | US AQI | Category |
|---|---|---|
| 0.0–9.0 | 0–50 | Good |
| 9.1–35.4 | 51–100 | Moderate |
| 35.5–55.4 | 101–150 | Unhealthy for Sensitive Groups |
| 55.5–125.4 | 151–200 | Unhealthy |
| 125.5–225.4 | 201–300 | Very Unhealthy |
| 225.5–325.4 | 301–500 | Hazardous |
For example, 35.4 µg/m³ corresponds to AQI 100 at the listed boundary. It does not mean AQI 35.4. Values beyond the displayed range should be identified as beyond the scale, not relabeled Good or silently discarded.
Why does a sensor disagree with AirNow?
Check the time window before assuming one is wrong. AirNow’s current particle AQI uses a NowCast based on recent observations; a sensor may show a much shorter average. The daily AQI is another product. AirNow’s time-frame explanation is the reference for that distinction.
Use this comparison sequence: match the pollutant, match the units, match the time, then inspect location and source. If one screen is an indoor sensor and the other represents a reporting area, write that difference down before interpreting the gap. Our monitor-versus-sensor guide explains the source labels used on BreatheCheck.
What should I check on a city page?
Open your city, read the source and timestamp, and use the AQI category guide for interpretation. A stale or missing value does not describe the air now. Our methodology explains how BreatheCheck handles missing sources and why its collected daily maxima are not official daily AQI reports.